DNA & RNA decontamination in the lab – freshly prepared from one tablet
One DN-X® tablet in 250 ml distilled water gives a freshly prepared working solution for suitable lab surfaces and PCR workstations.
Available from stock now.
- 1 tablet = 250 ml working solution
- Individually wrapped – jar of 10 tablets, box of 250 or 500 tablets
- Retest date: 24 months from date of manufacture
- Expert assessment: STR-PCR after treatment with no peaks above 50 RFU
- pUC18 experiment: native plasmid DNA no longer detectable after 30 s (n.d.)

Hi, I'm Ida from DN-X®.
“One tablet, 250 ml, freshly prepared. That's all I need.” I'm the face of DN-X® and I'll show you what is behind the tablet: data, experiments and how to use it.
1 tablet
= 250 ml working solution
10 tablets
per jar
250 / 500
tablets per box
Retest date
24 months from date of manufacture
Scientific comparison: densitometry profiles
Degradation of pUC18 plasmid DNA after 30 and 60 seconds

Key result: in all four conditions, no native pUC18 DNA is detectable in the DN-X® lanes (n.d.). In the comparator lanes, 26–72 % of the native plasmid DNA remains.
Only the gel regions of the native pUC18 conformations (shaded) are evaluated, including the upper, slower-migrating band. All curves are aligned to the same migration coordinate of the original gels (gel well and two marker bands).
Grey dashed and dotted lines – untreated control (C): pUC18 plasmid DNA without treatment, one control on each gel (= 100 %).
Dark blue lines – comparator: a commercially available, ready-to-use DNA/RNA decontamination solution. One line per gel lane, 3 lanes per condition.
Magenta lines – DN-X®: freshly prepared working solution (1 tablet in 250 ml distilled water). One line per gel lane, 3 lanes per condition.
Integrated peak area of native pUC18 DNA, % of the untreated control on the same gel (range across 3 lanes):
50 ng · 30 s: comparator 39–57 % · DN-X® n.d.
50 ng · 60 s: comparator 28–39 % · DN-X® n.d.
150 ng · 30 s: comparator 51–72 % · DN-X® n.d.
150 ng · 60 s: comparator 26–42 % · DN-X® n.d.
n.d. = no native pUC18 DNA detectable; signal at the level of the DNA-free blank lanes (3–12 %).
In-house densitometric evaluation by Allvater Biosolutions of the original gel images from an external laboratory (agarose gel electrophoresis, experiment of 13 October 2026; 50 ng and 150 ng pUC18 plasmid DNA in 10 µl, treated with 5 µl solution for 30 and 60 seconds at room temperature). Local background correction per lane; each lane normalised to the untreated control on the same gel.
After 30 seconds: no native DNA detectable.
“Look at the magenta curves.” In the pUC18 experiment of an external laboratory, native plasmid DNA was no longer detectable (n.d.) in any DN-X® lane after just 30 seconds, at both 50 ng and 150 ng DNA.


STR-PCR: forensic expert assessment
Dried STR-PCR product before and after treatment with DN-X® · original electropherograms
Key result: after treatment with DN-X®, no STR peaks above the analytical threshold of 50 RFU were detected.
Independent expert assessment by Univ.-Prof. Dr. Cornelius Courts, Forensic Molecular Genetics, University of Cologne. Dried STR-PCR product was analysed before and after treatment with DN-X® (GeneMapper IDX v1.6).
Before treatment (top): distinct allele peaks of several thousand RFU. After treatment with DN-X® (bottom): no peaks above the analytical threshold of 50 RFU in the experiment described.
How to read this: The two electropherograms have differently scaled Y axes (RFU) – top up to approx. 10,000 RFU, bottom up to approx. 35 RFU. Please read values only against the respective axis.
Original electropherogram excerpts, unaltered, from the Allvater document “Certificate of Confirmation” AV-DNX-COC-2026-001 (version 1.0, 1 July 2026). It summarises the expert assessment and is not a product certification. The statement applies to the experimental set-up described. Shown separately from the pUC18 experiment of the external laboratory.

Before: thousands of RFU. After: no peak above 50 RFU.
“This is what a clean result looks like.” In the forensic expert assessment by Univ.-Prof. Dr. Cornelius Courts (University of Cologne), no STR peaks above the analytical threshold of 50 RFU were detectable after treatment with DN-X®. The statement applies to the experimental set-up described.
Tablet instead of canister: economic and logistical advantages
Less mass, compact storage, defined preparation – for laboratories, distributors and kit manufacturers
Instead of shipping water, only the tablet travels to the lab.
Ready-to-use decontamination products consist mainly of water that is produced, filled, shipped and stored. With DN-X®, the water is only added on site.
- 12 kg instead of around 1,000 kg: 1,000 litres of working solution require 4,000 tablets of 3 g each – about 12 kg of tablets instead of around 1,000 kg of liquid (product mass only, without packaging).
- 125 litres from one box: Box 500 gives 125 litres, Box 250 gives 62.5 litres, a jar of 10 tablets gives 2.5 litres of working solution.
- Defined preparation: 1 tablet = 250 ml – no measuring out, easy to standardise, document and train.
- Prepared as needed: Only as much solution is prepared as is needed – this reduces unused leftovers.
- Long storage: Retest date: 24 months from date of manufacture.
- Individually wrapped: each tablet separately – suitable as a kit component for OEM and private label.
Comparison of product mass only, without packaging. No general freight or CO₂ saving can be derived from this; volume, packaging and transport route determine the actual logistics.
Prevent DNA contamination and clean PCR workstations
Freshly prepared instead of delivered ready-made
Unwanted DNA and RNA residues on work surfaces and lab equipment can contribute to contamination and false amplification in PCR analyses. To prevent PCR contamination, DNA contamination is removed regularly from lab surfaces and equipment. DN-X® is a DNA decontamination agent in tablet form for exactly this lab routine.
DN-X® is only prepared in the lab: dissolve one tablet in 250 ml distilled water, note the preparation date, wet the surface. Until then, DN-X® is stored compactly as a tablet.
Used in
- Molecular biology and genetic research
- PCR and qPCR laboratories
- Forensic genetics
- Biotechnology and pharmaceutical research
Product and pack sizes
Available from stock – for laboratories, distributors and kit manufacturers
Technical product data
- Preparation: 1 tablet = 250 ml working solution in distilled water
- Jar: 10 tablets, individually wrapped – item no. 90001730 (2.5 litres of working solution)
- Box 250: 250 tablets, individually wrapped – item no. 90001740 (62.5 litres of working solution)
- Box 500: 500 tablets, individually wrapped – item no. 90001741 (125 litres of working solution)
- Retest date: 24 months from date of manufacture – a retest date is not an automatic expiry date
Larger pack sizes as well as OEM and private-label versions on request.
Ordering
Order by e-mail stating item number, quantity, and delivery and invoice address. We will confirm delivery time and terms.
→ Downloads: instructions for use, safety data sheet and lab results
Efficacy, transparently documented
Two pieces of evidence – shown separately
Expert assessment – Univ.-Prof. Dr. Cornelius Courts
STR-PCR with dried PCR product: after treatment with DN-X®, no peaks above the analytical threshold of 50 RFU were reported.
Forensic Molecular Genetics, University of Cologne · AV-DNX-COC-2026-001 · The statement applies to the experimental set-up described.
Laboratory experiment – external laboratory
DNA degradation experiment of 13 October 2026 with pUC18 plasmid DNA (50 and 150 ng) after 30 and 60 seconds contact time, compared with a commercially available ready-to-use solution.
DN-X was tested in 250 ml distilled water. Experimental conditions and results can be found on the Efficacy page.
Frequently asked questions about DN-X®
Short answers
How is DN-X® prepared?
Dissolve one DN-X® tablet completely in 250 ml distilled water. For application, contact time and subsequent cleaning, the current instructions for use apply.
Do I need a safety data sheet for the working solution?
No. The prepared DN-X® working solution is not classified as hazardous under the CLP Regulation: a safety data sheet is not required under REACH and hazard labelling is not necessary. For your records we provide one voluntarily under Downloads – along with the safety data sheet for the tablet.
Which surfaces is DN-X® intended for?
For suitable laboratory work surfaces and equipment surfaces. Please observe the instructions for use and the equipment manufacturer's guidance.
Is DN-X® a disinfectant?
No. DN-X® is for DNA and RNA decontamination and does not replace a disinfectant for inactivating microorganisms.
Does DN-X® have a best-before date?
No. A retest date applies: 24 months from date of manufacture. A retest date is not an automatic expiry date.

Try it yourself.
“I'll be happy to send you a sample.” Just tell us your application, surfaces and country. We will get back to you with a sample, a quote or a suitable appointment.
Request a quote, sample or partnership
For laboratories, distributors and kit manufacturers
Tell us briefly what you would like to use DN-X® for. We will get back to you with a quote, a sample or a suitable appointment.
Request a sample
For laboratories: tell us your application, surfaces and country. Samples are provided by arrangement.
Request a quote
For laboratories and purchasing: jar of 10 tablets (item no. 90001730), Box 250 (item no. 90001740) or Box 500 (item no. 90001741). Please state pack size, quantity and country of delivery.
Become a distribution partner
For distributors and dealers: terms, pack sizes and marketing material for your range and your sales region.
→ Become a distribution partner
For OEM and kit manufacturers
DN-X® under your brand or as an individually wrapped kit component.
→ Discuss an OEM or kit project
All contact options and contacts can be found on the contact page.
DN-X® for your field (German pages): Forensics · PCR lab · Research · Biotech and pharma · Analytics